Stainless Steel KF25 Centering ring with Viton o-ring and Aluminum KF25 Clamp Included.
Equivelant to Agilent Varian Part Number SCRINTRPNW25
Replacement Filter Element Available - Item#: PN17938 Click Here
A&J Vacuum Services offers full repair/service of AJVS, along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
AJVS HEPA Inlet Trap Filter for All Vacuum Pumps CSL Series NW25, Electroless Nickel Finish, PN18653
Replacement Filter Element Available - Item#: PN17938 Click Here
Electroless Nickel Finish | |
Temp (continuous): | min -26°C (-15°F) max 104°C (220°F) |
Vacuum Leak Rate: | 1 x 10-5 mbar l/sec |
A&J Vacuum Services offers full repair/service of AJVS, along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Stainless Steel KF25 Centering ring with Viton o-ring and Aluminum KF25 Clamp Included.
Equivelant to Agilent Varian Part Number SCRINTRPNW25
Replacement Filter Element Available - Item#: PN17938 Click Here
A&J Vacuum Services offers full repair/service of AJVS, along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
AJVS HEPA Inlet Trap Filter for All Vacuum Pumps CSL Series NW25, Electroless Nickel Finish, PN18653
Replacement Filter Element Available - Item#: PN17938 Click Here
Electroless Nickel Finish | |
Temp (continuous): | min -26°C (-15°F) max 104°C (220°F) |
Vacuum Leak Rate: | 1 x 10-5 mbar l/sec |
A&J Vacuum Services offers full repair/service of AJVS, along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.