phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470
Item#: PN21835 Mfr Part#: 37470 Manufacturer: Brandtech
Condition: New
New BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470

Features:
  • PN 37470
  • Error limits ± mL: 0.2
  • Transparent
  • Pack of 2

PRICE: $260.26
WEB SAVINGS: $23.66
YOU PAY: $236.60
Item#: PN21835 Mfr Part#: 37470
BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470
Item#: PN21835 Mfr Part#: 37470 Manufacturer: Brandtech 12 months warranty

BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470


 

Overview

Class A, USP, certified volumetric flasks. These are supplied with a glass stopper with a dripping tip. Available in both transparent and amber color. High contrast blue enamel print on transparent flasks, and white on amber flasks, represent the optimum combination of resistance and readability. Available in all ISO sizes from 5mL to 2000mL. Made of low expansion coefficient, chemically resistant borosilicate 3.3. Volumetric flasks are indispensable for preparing dilutions and standard solutions. All BLAUBRAND® USP volumetric flasks are supplied with a batch number and an accompanying USP batch certificate in the original packaging.

Volumetric instruments according to USP error limits

Companies producing pharmaceutical products for the US market are supervised by US authorities, e.g. the FDA (Food and Drug Administration), and have to meet the requirements of the USP (United States Pharmacopeia). The current USP prescribes in section 31 the use of volumetric instruments with accuracy in accordance to class A of the ASTM standards and list those for volumetric flasks, transfer pipettes and burettes in tables. For graduated pipettes up to and including 10 mL size the error limits are mentioned in the text. BRAND volumetric instruments are manufactured according to the current DIN EN ISO standards. As the construction specifications are differently defined in the DIN EN ISO and ASTM standards, the error limits differ as well. With included USP certificates BRAND confirms for the delivered USP volumetric instruments that the class A error limits according to the USP or, rather, ASTM standards are met.

Every glass volumetric measuring instrument is individually calibrated. Computer-controlled systems ensure maximum precision in a fully automated production line. The final step of this Statistical Process Control is random sampling of finished product according to DIN ISO 3951. The quality management system applied at BRAND, which is certified according to DIN EN ISO 9001, is a combination of process monitoring and random checks with an accepted quality level (AQL) of approximately 0.4.

The batch certificate confirms that ASTM class A error limits required by USP are met. The certificate records the mean value, the standard deviation of the batch and the date of issue (batch number: year of manufacture/batch).

This item is non-returnable/non-refundable

BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470


Class A, USP, Certified Volumetric Flasks, Transparent

  Volume
   mL
Error limits
± mL
Stopper size
NS
Qty/Pack
Cat. No.
  5
0.02
10/19
2
36968
  10
0.02
10/19
2
36973
  20
0.02
10/19
2
36975
  25
0.03
10/19
2
36977
  50
0.05
12/21
2
36978
  100
0.08
14/23
2
36979
  200
0.10
14/23
2
36980
  250
0.12
14/23
2
36981
  500
0.20
19/26
2
36982
  1000
0.30
24/29
1
36983
  2000
0.50
29/32
1
36984
• High contrast blue enamel print

 

 

Class A, USP, Certified Volumetric Flasks, Amber

  Volume
   mL
Error limits
± mL
Stopper size
NS
Qty/Pack
Cat. No.
  5
0.02
10/19
2
37461
  10
0.02
10/19
2
37462
  20
0.02
10/19
2
37463
  25
0.03
10/19
2
37464
  50
0.05
12/21
2
37465
  100
0.08
14/23
2
37467
  200
0.10
14/23
2
37468
  250
0.12
14/23
2
37469
  500
0.20
19/26
2
37470
  1000
0.30
24/29
1
37471
• High contrast white enamel print
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470
Item#: PN21835 Mfr Part#: 37470 Manufacturer: Brandtech

BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470


 

Overview

Class A, USP, certified volumetric flasks. These are supplied with a glass stopper with a dripping tip. Available in both transparent and amber color. High contrast blue enamel print on transparent flasks, and white on amber flasks, represent the optimum combination of resistance and readability. Available in all ISO sizes from 5mL to 2000mL. Made of low expansion coefficient, chemically resistant borosilicate 3.3. Volumetric flasks are indispensable for preparing dilutions and standard solutions. All BLAUBRAND® USP volumetric flasks are supplied with a batch number and an accompanying USP batch certificate in the original packaging.

Volumetric instruments according to USP error limits

Companies producing pharmaceutical products for the US market are supervised by US authorities, e.g. the FDA (Food and Drug Administration), and have to meet the requirements of the USP (United States Pharmacopeia). The current USP prescribes in section 31 the use of volumetric instruments with accuracy in accordance to class A of the ASTM standards and list those for volumetric flasks, transfer pipettes and burettes in tables. For graduated pipettes up to and including 10 mL size the error limits are mentioned in the text. BRAND volumetric instruments are manufactured according to the current DIN EN ISO standards. As the construction specifications are differently defined in the DIN EN ISO and ASTM standards, the error limits differ as well. With included USP certificates BRAND confirms for the delivered USP volumetric instruments that the class A error limits according to the USP or, rather, ASTM standards are met.

Every glass volumetric measuring instrument is individually calibrated. Computer-controlled systems ensure maximum precision in a fully automated production line. The final step of this Statistical Process Control is random sampling of finished product according to DIN ISO 3951. The quality management system applied at BRAND, which is certified according to DIN EN ISO 9001, is a combination of process monitoring and random checks with an accepted quality level (AQL) of approximately 0.4.

The batch certificate confirms that ASTM class A error limits required by USP are met. The certificate records the mean value, the standard deviation of the batch and the date of issue (batch number: year of manufacture/batch).

BrandTech BLAUBRAND, Amber Volumetric Flask, Class A, USP, Certified, Glass Stopper, 500mL, 37470


Class A, USP, Certified Volumetric Flasks, Transparent

  Volume
   mL
Error limits
± mL
Stopper size
NS
Qty/Pack
Cat. No.
  5
0.02
10/19
2
36968
  10
0.02
10/19
2
36973
  20
0.02
10/19
2
36975
  25
0.03
10/19
2
36977
  50
0.05
12/21
2
36978
  100
0.08
14/23
2
36979
  200
0.10
14/23
2
36980
  250
0.12
14/23
2
36981
  500
0.20
19/26
2
36982
  1000
0.30
24/29
1
36983
  2000
0.50
29/32
1
36984
• High contrast blue enamel print

 

 

Class A, USP, Certified Volumetric Flasks, Amber

  Volume
   mL
Error limits
± mL
Stopper size
NS
Qty/Pack
Cat. No.
  5
0.02
10/19
2
37461
  10
0.02
10/19
2
37462
  20
0.02
10/19
2
37463
  25
0.03
10/19
2
37464
  50
0.05
12/21
2
37465
  100
0.08
14/23
2
37467
  200
0.10
14/23
2
37468
  250
0.12
14/23
2
37469
  500
0.20
19/26
2
37470
  1000
0.30
24/29
1
37471
• High contrast white enamel print
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.