Overview
These glass-clear tall-form cylinders are calibrated “to contain” and are Class A per DIN 12681 and ISO 6706. Hexagonal base provides stability. Supplied certificate includes mean test value and lot (lot and year are imprinted on product). Thermal stress up to 121°C (autoclaving) does not cause permanent exceeding of the tolerance limits. However, to preserve markings (cat. no. V64604 – V65304), cleaning at no higher than 60°C is recommended. For autoclaving, the design with raised graduations (cat. no. V64614 – V65414) is recommended.
Class A Graduated Cylinders, PMP, Certified
Volume
mL |
Tolerance
± mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|---|
10
|
0.10
|
0.20
|
145
|
15
|
2
|
V64614
|
25
|
0.25
|
0.50
|
170
|
22
|
2
|
V64714
|
50
|
0.50
|
1.00
|
200
|
27
|
2
|
V64814
|
100
|
0.50
|
1.00
|
250
|
33
|
2
|
V64914
|
250
|
1.00
|
2.00
|
315
|
44
|
2
|
V65014
|
500
|
2.50
|
5.00
|
360
|
58
|
1
|
V65114
|
1000
|
5.00
|
10.00
|
440
|
69
|
1
|
V65214
|
2000
|
10.00
|
20.00
|
535
|
97
|
1
|
V65414
|
Class A Graduated Cylinders, PMP, Certified
Volume
mL |
Tolerance
± mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|---|
10
|
0.10
|
0.20
|
145
|
15
|
2
|
V64604
|
25
|
0.25
|
0.50
|
170
|
21
|
2
|
V64704
|
50
|
0.50
|
1.00
|
200
|
27
|
2
|
V64804
|
100
|
0.50
|
1.00
|
250
|
33
|
2
|
V64904
|
250
|
1.00
|
2.00
|
315
|
44
|
2
|
V65004
|
500
|
2.50
|
5.00
|
360
|
58
|
1
|
V65104
|
1000
|
5.00
|
10.00
|
440
|
69
|
1
|
V65204
|
2000
|
10.00
|
20.00
|
482
|
97
|
1
|
V65304
|
• Molded graduations with ring marks at major increments
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
These glass-clear tall-form cylinders are calibrated “to contain” and are Class A per DIN 12681 and ISO 6706. Hexagonal base provides stability. Supplied certificate includes mean test value and lot (lot and year are imprinted on product). Thermal stress up to 121°C (autoclaving) does not cause permanent exceeding of the tolerance limits. However, to preserve markings (cat. no. V64604 – V65304), cleaning at no higher than 60°C is recommended. For autoclaving, the design with raised graduations (cat. no. V64614 – V65414) is recommended.
Class A Graduated Cylinders, PMP, Certified
Volume
mL |
Tolerance
± mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|---|
10
|
0.10
|
0.20
|
145
|
15
|
2
|
V64614
|
25
|
0.25
|
0.50
|
170
|
22
|
2
|
V64714
|
50
|
0.50
|
1.00
|
200
|
27
|
2
|
V64814
|
100
|
0.50
|
1.00
|
250
|
33
|
2
|
V64914
|
250
|
1.00
|
2.00
|
315
|
44
|
2
|
V65014
|
500
|
2.50
|
5.00
|
360
|
58
|
1
|
V65114
|
1000
|
5.00
|
10.00
|
440
|
69
|
1
|
V65214
|
2000
|
10.00
|
20.00
|
535
|
97
|
1
|
V65414
|
Class A Graduated Cylinders, PMP, Certified
Volume
mL |
Tolerance
± mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|---|
10
|
0.10
|
0.20
|
145
|
15
|
2
|
V64604
|
25
|
0.25
|
0.50
|
170
|
21
|
2
|
V64704
|
50
|
0.50
|
1.00
|
200
|
27
|
2
|
V64804
|
100
|
0.50
|
1.00
|
250
|
33
|
2
|
V64904
|
250
|
1.00
|
2.00
|
315
|
44
|
2
|
V65004
|
500
|
2.50
|
5.00
|
360
|
58
|
1
|
V65104
|
1000
|
5.00
|
10.00
|
440
|
69
|
1
|
V65204
|
2000
|
10.00
|
20.00
|
482
|
97
|
1
|
V65304
|
• Molded graduations with ring marks at major increments
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.