Overview
Tinted volumetric flasks of polymethylpentene (PMP) offer superior opacity to ultraviolet light, as well as much of the visible spectrum, compared with amber glass. They are also light weight and offer superior break resistance. An excellent choice for measurement of light-sensitive materials.
Flasks are available in sizes from 10mL to 1000mL and are supplied with tinted PP screw caps. They offer accuracy to Class A standards per DIN EN ISO 1042, even after autoclaving at temperatures up to 121°C (to preserve markings, cleaning at no higher than 60°C is recommended). Flasks may also be sterilized with formalin or ethanol, or by β-radiation, and are microwavable. Excellent resistance to acids, alkalis and alcohols at room temperature, and good-to-limited (short term exposure) resistance to aliphatic hydrocarbons, aldehydes, ketones and esters. They are not suitable for use with aromatic or halogenated hydrocarbons, ethers, oxidizing acids or oxidizing reagents.
Each flask is individually calibrated “to-contain” (‘In’) at a reference temperature of 20°C, individually ring-marked, for accuracy, imprinted with a lot-number, and shipped with a lot certificate. The high contrast ring-mark ensures an accurate reading of the meniscus.
Class A Volumetric Flask, PMP, with Screw Cap, PP, Certified
Volume
mL |
Tolerance
±mL |
Height
mm |
Thread
GL |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
10
|
0.04
|
90
|
18
|
2
|
V670040
|
25
|
0.04
|
115
|
18
|
2
|
V671040
|
50
|
0.06
|
150
|
18
|
2
|
V672040
|
100
|
0.10
|
180
|
18
|
2
|
V673040
|
250
|
0.15
|
235
|
25
|
2
|
V674040
|
500
|
0.25
|
270
|
25
|
2
|
V675040
|
1000
|
0.40
|
310
|
32
|
1
|
V676040
|
Class A Volumetric Flask, PMP, with NS Stopper, PP, Certified
Volume
mL |
Tolerance
±mL |
Height
mm |
Stopper
NS |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
10
|
0.04
|
90
|
10/19
|
2
|
V670950
|
25
|
0.04
|
115
|
10/19
|
2
|
V671950
|
50
|
0.06
|
150
|
12/21
|
2
|
V672950
|
100
|
0.10
|
180
|
14/23
|
2
|
V673950
|
250
|
0.15
|
235
|
19/26
|
2
|
V674950
|
500
|
0.25
|
270
|
19/26
|
2
|
V675950
|
1000
|
0.40
|
310
|
24/29
|
1
|
V676950
|
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
Tinted volumetric flasks of polymethylpentene (PMP) offer superior opacity to ultraviolet light, as well as much of the visible spectrum, compared with amber glass. They are also light weight and offer superior break resistance. An excellent choice for measurement of light-sensitive materials.
Flasks are available in sizes from 10mL to 1000mL and are supplied with tinted PP screw caps. They offer accuracy to Class A standards per DIN EN ISO 1042, even after autoclaving at temperatures up to 121°C (to preserve markings, cleaning at no higher than 60°C is recommended). Flasks may also be sterilized with formalin or ethanol, or by β-radiation, and are microwavable. Excellent resistance to acids, alkalis and alcohols at room temperature, and good-to-limited (short term exposure) resistance to aliphatic hydrocarbons, aldehydes, ketones and esters. They are not suitable for use with aromatic or halogenated hydrocarbons, ethers, oxidizing acids or oxidizing reagents.
Each flask is individually calibrated “to-contain” (‘In’) at a reference temperature of 20°C, individually ring-marked, for accuracy, imprinted with a lot-number, and shipped with a lot certificate. The high contrast ring-mark ensures an accurate reading of the meniscus.
Class A Volumetric Flask, PMP, with Screw Cap, PP, Certified
Volume
mL |
Tolerance
±mL |
Height
mm |
Thread
GL |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
10
|
0.04
|
90
|
18
|
2
|
V670040
|
25
|
0.04
|
115
|
18
|
2
|
V671040
|
50
|
0.06
|
150
|
18
|
2
|
V672040
|
100
|
0.10
|
180
|
18
|
2
|
V673040
|
250
|
0.15
|
235
|
25
|
2
|
V674040
|
500
|
0.25
|
270
|
25
|
2
|
V675040
|
1000
|
0.40
|
310
|
32
|
1
|
V676040
|
Class A Volumetric Flask, PMP, with NS Stopper, PP, Certified
Volume
mL |
Tolerance
±mL |
Height
mm |
Stopper
NS |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
10
|
0.04
|
90
|
10/19
|
2
|
V670950
|
25
|
0.04
|
115
|
10/19
|
2
|
V671950
|
50
|
0.06
|
150
|
12/21
|
2
|
V672950
|
100
|
0.10
|
180
|
14/23
|
2
|
V673950
|
250
|
0.15
|
235
|
19/26
|
2
|
V674950
|
500
|
0.25
|
270
|
19/26
|
2
|
V675950
|
1000
|
0.40
|
310
|
24/29
|
1
|
V676950
|
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.