Overview
These Graduated Pitchers are available in highly transparent PP (polypropylene) or crystal clear SAN (styrene acrylonitrile copolymer), and provide easy measurement of approximate volumes with easy-grip handles. The V48-series pitchers are nesting to conserve space and have blue screened graduations. All others have molded graduations, with or without blue screened graduations. The PP pitchers are autoclavable at 121°C (2 bar) according to DIN EN 285. However, to preserve markings on pitchers with colored overprint (cat. no. V446081-V445081, V480941-V484941), cleaning at no higher than 60°C is recommended.
Graduated Pitchers, PP
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
50
|
2
|
70
|
40
|
24
|
V446941
|
100
|
2
|
80
|
50
|
24
|
V447941
|
250
|
5
|
120
|
70
|
12
|
V440941
|
500
|
10
|
133
|
91
|
12
|
V441941
|
1000
|
20
|
170
|
116
|
6
|
V442941
|
2000
|
50
|
215
|
150
|
6
|
V443941
|
3000
|
50
|
242
|
170
|
6
|
V444941
|
5000
|
100
|
270
|
210
|
6
|
V445941
|
Graduated Pitchers, PP
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
50
|
2
|
70
|
40
|
24
|
V446081
|
100
|
2
|
80
|
50
|
24
|
V447081
|
250
|
5
|
120
|
70
|
12
|
V440081
|
500
|
10
|
133
|
91
|
12
|
V441081
|
1000
|
20
|
182
|
116
|
6
|
V442081
|
2000
|
50
|
215
|
150
|
6
|
V443081
|
3000
|
50
|
242
|
170
|
6
|
V444081
|
5000
|
100
|
270
|
210
|
6
|
V445081
|
Graduated Pitchers, SAN
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
250
|
5
|
120
|
70
|
12
|
V44091
|
500
|
10
|
133
|
91
|
12
|
V44191
|
1000
|
10
|
170
|
116
|
6
|
V44291
|
2000
|
20
|
215
|
150
|
6
|
V44391
|
3000
|
50
|
242
|
170
|
6
|
V44491
|
Nesting Pitchers, PP
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
250
|
5
|
115
|
75
|
12
|
V480941
|
500
|
10
|
140
|
100
|
12
|
V481941
|
1000
|
10
|
167
|
125
|
12
|
V482941
|
2000
|
20
|
212
|
148
|
12
|
V483941
|
3000
|
50
|
242
|
170
|
12
|
V484941
|
• Graduations are printed with screening for easy, accurate measurements
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
These Graduated Pitchers are available in highly transparent PP (polypropylene) or crystal clear SAN (styrene acrylonitrile copolymer), and provide easy measurement of approximate volumes with easy-grip handles. The V48-series pitchers are nesting to conserve space and have blue screened graduations. All others have molded graduations, with or without blue screened graduations. The PP pitchers are autoclavable at 121°C (2 bar) according to DIN EN 285. However, to preserve markings on pitchers with colored overprint (cat. no. V446081-V445081, V480941-V484941), cleaning at no higher than 60°C is recommended.
Graduated Pitchers, PP
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
50
|
2
|
70
|
40
|
24
|
V446941
|
100
|
2
|
80
|
50
|
24
|
V447941
|
250
|
5
|
120
|
70
|
12
|
V440941
|
500
|
10
|
133
|
91
|
12
|
V441941
|
1000
|
20
|
170
|
116
|
6
|
V442941
|
2000
|
50
|
215
|
150
|
6
|
V443941
|
3000
|
50
|
242
|
170
|
6
|
V444941
|
5000
|
100
|
270
|
210
|
6
|
V445941
|
Graduated Pitchers, PP
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
50
|
2
|
70
|
40
|
24
|
V446081
|
100
|
2
|
80
|
50
|
24
|
V447081
|
250
|
5
|
120
|
70
|
12
|
V440081
|
500
|
10
|
133
|
91
|
12
|
V441081
|
1000
|
20
|
182
|
116
|
6
|
V442081
|
2000
|
50
|
215
|
150
|
6
|
V443081
|
3000
|
50
|
242
|
170
|
6
|
V444081
|
5000
|
100
|
270
|
210
|
6
|
V445081
|
Graduated Pitchers, SAN
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
250
|
5
|
120
|
70
|
12
|
V44091
|
500
|
10
|
133
|
91
|
12
|
V44191
|
1000
|
10
|
170
|
116
|
6
|
V44291
|
2000
|
20
|
215
|
150
|
6
|
V44391
|
3000
|
50
|
242
|
170
|
6
|
V44491
|
Nesting Pitchers, PP
Volume
mL |
Graduation
mL |
Height
mm |
Diameter
mm |
Qty/Pack
|
Cat. No.
|
---|---|---|---|---|---|
250
|
5
|
115
|
75
|
12
|
V480941
|
500
|
10
|
140
|
100
|
12
|
V481941
|
1000
|
10
|
167
|
125
|
12
|
V482941
|
2000
|
20
|
212
|
148
|
12
|
V483941
|
3000
|
50
|
242
|
170
|
12
|
V484941
|
• Graduations are printed with screening for easy, accurate measurements
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.