phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016
Item#: PN23299 Mfr Part#: C10501016 Manufacturer: Vacuum Fittings
Condition: New In Stock
New Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016

Features:
  • OEM Part
  • P/N C10501016
  • Stainless Steel
  • For Corrosive Versions

PRICE: $140.00
WEB SAVINGS: $30.00
YOU PAY: $110.00
Item#: PN23299 Mfr Part#: C10501016
Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016
Item#: PN23299 Mfr Part#: C10501016 Manufacturer: Vacuum Fittings

Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016

Stainles Steel Adaptor fits the following Edwards Scroll Pump

nXDS 6i, nXDS 6R, nXDS 6 IC

nXDS 10i, nXDS 10R, nXDS 10 IC

nXDS 15i, nXDS 15R, nXDS 15 IC

Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016

Stainles Steel Adaptor fits the following Edwards Scroll Pump

nXDS 6i, nXDS 6R, nXDS 6 IC

nXDS 10i, nXDS 10R, nXDS 10 IC

nXDS 15i, nXDS 15R, nXDS 15 IC

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016
Item#: PN23299 Mfr Part#: C10501016 Manufacturer: Vacuum Fittings

Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016

Stainles Steel Adaptor fits the following Edwards Scroll Pump

nXDS 6i, nXDS 6R, nXDS 6 IC

nXDS 10i, nXDS 10R, nXDS 10 IC

nXDS 15i, nXDS 15R, nXDS 15 IC

Edwards NW 25 Adaptor Flange 3/4 BSP, Stainless Steel, C10501016

Stainles Steel Adaptor fits the following Edwards Scroll Pump

nXDS 6i, nXDS 6R, nXDS 6 IC

nXDS 10i, nXDS 10R, nXDS 10 IC

nXDS 15i, nXDS 15R, nXDS 15 IC

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.