The ASM 182/192 series of helium leak detectors includes the most up-to-date evolutions of Adixen leak detectors, thousands of which are utilized in successful daily operation throughout the world in various applications. These include applications within the automotive, chemical and mechanical, electrical, electronics and packaging industries, as well as in quality control and maintenance of semiconductor processing systems, blister testing in the pharmaceutical industry, among other uses. This series of leak detectors offer unique features including high sensitivity (5 x 10^(-12) mbar l/s) and fast response time while in spraying mode.
Additionally, the ASM 182/192 series is extremely flexible with an emphasis on simplified operability and a user-friendly interface. Automatic operation is provided throughout the range of processes, including atmospheric sniffer tests, gas line and tube testing, large gross leak mode and ultra-sensitive vacuum fine leak mode, readily available basic functions, combined digital and analog display, as well as advanced functions for convenience.
Among this series of Pfeiffer Adixen leak detectors, the 192 T2D+ is a standout leading innovation. It is a console leak detector featuring the option of one or two dry pumps with a backing capacity of 25 m^3/h and 50 m^3/h, respectively. The product is ideal for industrial applications and environments involving large, complex systems with little capacity for error. The Adixen 192 T2D+ is likewise a reliable leak detector option for severe environments and circumstances. Its high helium pumping speed of 20 liters per second allows for a quickened response time, and the application arrives with an available test chamber accessory for user convenience.
Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.
Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Manual
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Broshure
A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T2D+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Backing Pump | Oil Free Backing Pump |
Backing Pump Capacity | 25 m³/h | 14.71 cfm | 416.67 l/min |
Detectable Gases | 4He |
Dimensions (L x W x H) | 594 x 692 x 933 mm | 23.39 x 27.24 x 36.73 inch |
Flange Model (Inlet) | DN 50 ISO-KF |
I/O Interfaces | Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure) |
Language | English |
Mains Cable | Yes, US power cable (15 A) |
Minimum Detectable Leak Rate for Helium (Sniffing Leak Detection) | 1 * 10^[-8] Pa m^3/s | 7.5 * 10^[-8] Torr l/s | 1 * 10^[-7] mbar l/s |
Minimum Detectable Leak Rate for Helium (Vacuum Leak Detection) | 5 * 10^[-13] Pa m³/s |
Noise Level | 66 dB(A) |
Power Consumption (Maximum) | 1000 W |
Pumping Speed for He | 20 l/s |
Sound Pressure Level | 66 dB(A) |
Start-Up Yime (20°C) with Calibration | 5 min |
Start-Up Time (20°C) Without Calibration | 3.5 min |
Supply | 110 – 130 V, 50/60 Hz |
Test Method | Vacuum and Sniffing Leak Detection |
Type | High Performance - Compact |
User Interface | Graphic Color Touch Screen |
Weight | 157 kg | 346.12 lb |
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Manual
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Broshure
A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T2D+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The ASM 182/192 series of helium leak detectors includes the most up-to-date evolutions of Adixen leak detectors, thousands of which are utilized in successful daily operation throughout the world in various applications. These include applications within the automotive, chemical and mechanical, electrical, electronics and packaging industries, as well as in quality control and maintenance of semiconductor processing systems, blister testing in the pharmaceutical industry, among other uses. This series of leak detectors offer unique features including high sensitivity (5 x 10^(-12) mbar l/s) and fast response time while in spraying mode.
Additionally, the ASM 182/192 series is extremely flexible with an emphasis on simplified operability and a user-friendly interface. Automatic operation is provided throughout the range of processes, including atmospheric sniffer tests, gas line and tube testing, large gross leak mode and ultra-sensitive vacuum fine leak mode, readily available basic functions, combined digital and analog display, as well as advanced functions for convenience.
Among this series of Pfeiffer Adixen leak detectors, the 192 T2D+ is a standout leading innovation. It is a console leak detector featuring the option of one or two dry pumps with a backing capacity of 25 m^3/h and 50 m^3/h, respectively. The product is ideal for industrial applications and environments involving large, complex systems with little capacity for error. The Adixen 192 T2D+ is likewise a reliable leak detector option for severe environments and circumstances. Its high helium pumping speed of 20 liters per second allows for a quickened response time, and the application arrives with an available test chamber accessory for user convenience.
Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.
Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Manual
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Broshure
A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T2D+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Backing Pump | Oil Free Backing Pump |
Backing Pump Capacity | 25 m³/h | 14.71 cfm | 416.67 l/min |
Detectable Gases | 4He |
Dimensions (L x W x H) | 594 x 692 x 933 mm | 23.39 x 27.24 x 36.73 inch |
Flange Model (Inlet) | DN 50 ISO-KF |
I/O Interfaces | Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure) |
Language | English |
Mains Cable | Yes, US power cable (15 A) |
Minimum Detectable Leak Rate for Helium (Sniffing Leak Detection) | 1 * 10^[-8] Pa m^3/s | 7.5 * 10^[-8] Torr l/s | 1 * 10^[-7] mbar l/s |
Minimum Detectable Leak Rate for Helium (Vacuum Leak Detection) | 5 * 10^[-13] Pa m³/s |
Noise Level | 66 dB(A) |
Power Consumption (Maximum) | 1000 W |
Pumping Speed for He | 20 l/s |
Sound Pressure Level | 66 dB(A) |
Start-Up Yime (20°C) with Calibration | 5 min |
Start-Up Time (20°C) Without Calibration | 3.5 min |
Supply | 110 – 130 V, 50/60 Hz |
Test Method | Vacuum and Sniffing Leak Detection |
Type | High Performance - Compact |
User Interface | Graphic Color Touch Screen |
Weight | 157 kg | 346.12 lb |
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Manual
Click Here for Pfeiffer/Adixen ASM 192 T2D+ Broshure
A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T2D+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.