New Pfeiffer DCU180 Turbo Coontroller PMC01821 Features;
The DCU 180 / PM C011 821 is a display and control unit for Pfeiffer Vacuum vacuum pumps with integrated electronic drive unit.
This DCU 180 displays all control parameters for the electronic drive unit. It is also possible to connect a pressure measuring vacuum gauge directlyy to the back of the DCU 180.
HiPace stands for a complete line of compact yet powerful turbopumps featuring pumping speeds that range from 10 – 800 liters per second. It offers a cost-effective yet flexible installation in any orientation. The proven bearing system affords unrivaled dependability. The improved rotor design makes for higher pumping speeds, higher backing pump compatibility and higher gas throughputs coupled with very good compression for light gases. The new, integrated drive electronics reduce the need for cumbersome and costly cabling.
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821 , DCU180 Controller
New Pfeiffer DCU 180 / PM C01 821 Technical data:
Ambient temperature | 5-50 °C |
Mains requirement: frequency (range) | 50/60 Hz |
Mains requirement: power consumption | 210 VA |
Mains requirement: voltage (range) | 115-230 (-20 - +15 %) V AC |
OuTPU t current | 7.5 A |
OuTPU t voltage | 24 (± 2 %) V DC |
Protection category | IP 20 |
Weight | 1.7 kg |
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
New Pfeiffer DCU180 Turbo Coontroller PMC01821 Features;
The DCU 180 / PM C011 821 is a display and control unit for Pfeiffer Vacuum vacuum pumps with integrated electronic drive unit.
This DCU 180 displays all control parameters for the electronic drive unit. It is also possible to connect a pressure measuring vacuum gauge directlyy to the back of the DCU 180.
HiPace stands for a complete line of compact yet powerful turbopumps featuring pumping speeds that range from 10 – 800 liters per second. It offers a cost-effective yet flexible installation in any orientation. The proven bearing system affords unrivaled dependability. The improved rotor design makes for higher pumping speeds, higher backing pump compatibility and higher gas throughputs coupled with very good compression for light gases. The new, integrated drive electronics reduce the need for cumbersome and costly cabling.
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821 , DCU180 Controller
New Pfeiffer DCU 180 / PM C01 821 Technical data:
Ambient temperature | 5-50 °C |
Mains requirement: frequency (range) | 50/60 Hz |
Mains requirement: power consumption | 210 VA |
Mains requirement: voltage (range) | 115-230 (-20 - +15 %) V AC |
OuTPU t current | 7.5 A |
OuTPU t voltage | 24 (± 2 %) V DC |
Protection category | IP 20 |
Weight | 1.7 kg |
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.