Overview:
The Oerlikon / Leybold D8B Seal Kit includes everything needed for light overhauls on the Oerlikon / Leybold D8B Rotary Vane Vacuum Pump.
We also do minor and major repairs for all Oerlikon / Leybold Rotary Vane Vacuum Pumps.
Oerlikon / Leybold D8B Seal Kit contains the following parts:
DESCRIPTION | PART NO. | QTY |
Felt Pad |
L15108035 |
1 |
Coupling |
L20009094 |
1 |
Coupling Gasket |
L20010731 |
1 |
Non-Return Spring |
L22161031 |
1 |
Oil Flow Spring |
L22161040 |
1 |
Viton Shaft Seal |
L23953006 |
2 |
Oil Plug Gasket |
L23955165 |
3 |
Teflon Plug Gasket |
L23955165T |
3 |
O-Ring |
L23970015 |
1 |
O-Ring |
L23970108 |
2 |
O-Ring |
L23970147 |
1 |
O-Ring |
L23970163 |
2 |
O-Ring |
L23970176 |
2 |
O-Ring |
L23970509 |
1 |
Module Gasket |
L23973037 |
1 |
Gasket |
L23973043 |
1 |
Flat Gasket |
L23973044 |
1 |
Case Gasket |
L23973047 |
1 |
Sight Glass Gasket |
L23973057 |
1 |
Viton Float Seal |
L23973146 |
1 |
Non-Return Valve |
L34861028 |
1 |
GB Seal |
L34861029 |
1 |
Internal Demister |
L39026011 |
1 |
Viton Valve Disk |
L40159003 |
1 |
THERE ARE NO RETURNS ON THIS PRODUCT.
Oerlikon / Leybold D8B Rotary Vane Vacuum Pump Seal Kit, 19120D8B
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview:
The Oerlikon / Leybold D8B Seal Kit includes everything needed for light overhauls on the Oerlikon / Leybold D8B Rotary Vane Vacuum Pump.
We also do minor and major repairs for all Oerlikon / Leybold Rotary Vane Vacuum Pumps.
Oerlikon / Leybold D8B Seal Kit contains the following parts:
DESCRIPTION | PART NO. | QTY |
Felt Pad |
L15108035 |
1 |
Coupling |
L20009094 |
1 |
Coupling Gasket |
L20010731 |
1 |
Non-Return Spring |
L22161031 |
1 |
Oil Flow Spring |
L22161040 |
1 |
Viton Shaft Seal |
L23953006 |
2 |
Oil Plug Gasket |
L23955165 |
3 |
Teflon Plug Gasket |
L23955165T |
3 |
O-Ring |
L23970015 |
1 |
O-Ring |
L23970108 |
2 |
O-Ring |
L23970147 |
1 |
O-Ring |
L23970163 |
2 |
O-Ring |
L23970176 |
2 |
O-Ring |
L23970509 |
1 |
Module Gasket |
L23973037 |
1 |
Gasket |
L23973043 |
1 |
Flat Gasket |
L23973044 |
1 |
Case Gasket |
L23973047 |
1 |
Sight Glass Gasket |
L23973057 |
1 |
Viton Float Seal |
L23973146 |
1 |
Non-Return Valve |
L34861028 |
1 |
GB Seal |
L34861029 |
1 |
Internal Demister |
L39026011 |
1 |
Viton Valve Disk |
L40159003 |
1 |
THERE ARE NO RETURNS ON THIS PRODUCT.
Oerlikon / Leybold D8B Rotary Vane Vacuum Pump Seal Kit, 19120D8B
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.