The Vacuubrand DCP 3000 Vacuum Gauge is an outstanding product to be used for Rough and fine vacuum. A large and user friendly illuminated display shows the measured values of all vacuum sensors by a simple turn of a button.
The Vacuubrand VSP 3000 (636163) Pirani vacuum sensor with unique ceramic diaphragm measures from atmospheric pressure down to 10-3 mbar. Vacuubrand VSK3000 sensor features a much better chemical resistance and ruggedness than conventional Pirani sensors with their fragile metallic spiral-wound filament.
Vacuubrand DCP 3000 offers simultaneous connection of up to eight vacuum sensors which alloes flexable measuring on the spot.
The DCP3000 is equipped with VACUU·BUS® (Digital Bus System) feature which allows the gauge to communicate with external components.
The Vacuubrand DCP 3000 / 683190 offers fully automatic configuration, unified plug connections and cable lenghts up to 30 meters
A&J Vacuum Services offers full repair/service of Vacuubrand , along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Technical data | Unit | Set DCP 3000 + VSP 3000 |
---|---|---|
Vacuum sensor | VSP 3000 | |
Cable length of vacuum sensor | m | 2 |
Upper measuring limit | mbar/torr | 1 x 103 / 7.5 x 102 |
Lower measuring limit | mbar/torr | 1 x 10-3 / 1 x 10-3 |
Measurement principle | Thermal conductivity (Pirani), chemically resistant plastics / ceramics | |
Accuracy of measurement | +- 15% of indicated value in the range 0.01-10 mbar/hPa/torr | |
Ambient temperature range (operation) | °C | 10 - 40 |
Ambient temperature range (storage) | °C | -10 - 60 |
Max. media temp. for continuous operation / short times | °C | 40 / 80 |
Material of outer housing | Robust plastic housing with good chemical resistance | |
Degree of protection | IP 20 | |
Degree of protection of front side (also built-in version) | IP 42 | |
Max. power for VACUU·BUS® (24V DC) | 4 A | |
Cable length of external power supply | m | 2 |
Interface | RS 232C | |
Dimensions (L x W x H) | mm | 144 x 124 x 114 |
Weight | kg | 0.44 |
Items supplied | Vacuum gauge with external vacuum sensor VSP 3000, ready for operation, with wall-plug power supply and manual. |
A&J Vacuum Services offers full repair/service of Vacuubrand , along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The Vacuubrand DCP 3000 Vacuum Gauge is an outstanding product to be used for Rough and fine vacuum. A large and user friendly illuminated display shows the measured values of all vacuum sensors by a simple turn of a button.
The Vacuubrand VSP 3000 (636163) Pirani vacuum sensor with unique ceramic diaphragm measures from atmospheric pressure down to 10-3 mbar. Vacuubrand VSK3000 sensor features a much better chemical resistance and ruggedness than conventional Pirani sensors with their fragile metallic spiral-wound filament.
Vacuubrand DCP 3000 offers simultaneous connection of up to eight vacuum sensors which alloes flexable measuring on the spot.
The DCP3000 is equipped with VACUU·BUS® (Digital Bus System) feature which allows the gauge to communicate with external components.
The Vacuubrand DCP 3000 / 683190 offers fully automatic configuration, unified plug connections and cable lenghts up to 30 meters
A&J Vacuum Services offers full repair/service of Vacuubrand , along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Technical data | Unit | Set DCP 3000 + VSP 3000 |
---|---|---|
Vacuum sensor | VSP 3000 | |
Cable length of vacuum sensor | m | 2 |
Upper measuring limit | mbar/torr | 1 x 103 / 7.5 x 102 |
Lower measuring limit | mbar/torr | 1 x 10-3 / 1 x 10-3 |
Measurement principle | Thermal conductivity (Pirani), chemically resistant plastics / ceramics | |
Accuracy of measurement | +- 15% of indicated value in the range 0.01-10 mbar/hPa/torr | |
Ambient temperature range (operation) | °C | 10 - 40 |
Ambient temperature range (storage) | °C | -10 - 60 |
Max. media temp. for continuous operation / short times | °C | 40 / 80 |
Material of outer housing | Robust plastic housing with good chemical resistance | |
Degree of protection | IP 20 | |
Degree of protection of front side (also built-in version) | IP 42 | |
Max. power for VACUU·BUS® (24V DC) | 4 A | |
Cable length of external power supply | m | 2 |
Interface | RS 232C | |
Dimensions (L x W x H) | mm | 144 x 124 x 114 |
Weight | kg | 0.44 |
Items supplied | Vacuum gauge with external vacuum sensor VSP 3000, ready for operation, with wall-plug power supply and manual. |
A&J Vacuum Services offers full repair/service of Vacuubrand , along with all other brands offered on our website. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.