Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB
Item#: PN15507 Mfr Part#: 3617OB Manufacturer: Solvay Solexis
Condition: New
New Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg

Features:
  • PN 3617OB
  • Density: 1.89g/cm3
  • Solvay Solexis Y L-VAC 16/6
  • Vacuum Pump Lubricant

Price upon request
Item#: PN15507 Mfr Part#: 3617OB
Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB
Item#: PN15507 Mfr Part#: 3617OB Manufacturer: Solvay Solexis

Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB


Overview

Fomblin PFPE fluid can be used in diffusion pumps without any modification to the pump. The major advantage in changing to Fomblin fluid is the reduction in contamination of the vacuum apparatus due to their very low backstreaming characteristics and elimination of solid deposit formation.

Working in the appropriate temperature range, the use of a cooling baffle is not critical with regard to ultimate pressure value, but best stability performance have been obtained with a single water cooled baffle. Low ultimate pressure is a typical benefit.

It is recommended that fluid temperature be kept below 280 °C for long fluid life. Under recommended operating procedures, Fomblin PFPE fluids will not decompose. However, gross pump misuse above 290 °C could result in partial decomposition and release of toxic gases. Improved safety can be obtained by absorbing the gases in a glass tube filled with granular calcium oxide at the end of the vacuum system.

Applications

Fomblin fluids are suggested for applications requiring the highest quality vacuum such as in scanning electron and transmission microscopes, mass spectrometers, particle accelerators, ion implantation, plasma and vapor deposition processes.

In addition, it is suggested for pumps handling reactive gases such as UF6, F2, oxygen, ozone and tritium, as the fluid can be used in direct contact with these gases without reaction and fluid degradation.

 

 


A&J Vacuum repairs / rebuilds and services all Vacuum Pumps, including Turbo Vacuum Pumps and Rotary Vane Pumps, Pumping Stations.  Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

This item is non-returnable/non-refundable

Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB


Technical Data:

Density: 1.89g/cm3

Viscosity Measurement: 110

Kinematic Viscocity: 168 cSt

Vapor Pressure: 2.67E-9 bar @ 20 degrees Celsius

 

 


A&J Vacuum repairs / rebuilds and services all Vacuum Pumps, including Turbo Vacuum Pumps and Rotary Vane Pumps, Pumping Stations.  Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB
Item#: PN15507 Mfr Part#: 3617OB Manufacturer: Solvay Solexis

Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB


Overview

Fomblin PFPE fluid can be used in diffusion pumps without any modification to the pump. The major advantage in changing to Fomblin fluid is the reduction in contamination of the vacuum apparatus due to their very low backstreaming characteristics and elimination of solid deposit formation.

Working in the appropriate temperature range, the use of a cooling baffle is not critical with regard to ultimate pressure value, but best stability performance have been obtained with a single water cooled baffle. Low ultimate pressure is a typical benefit.

It is recommended that fluid temperature be kept below 280 °C for long fluid life. Under recommended operating procedures, Fomblin PFPE fluids will not decompose. However, gross pump misuse above 290 °C could result in partial decomposition and release of toxic gases. Improved safety can be obtained by absorbing the gases in a glass tube filled with granular calcium oxide at the end of the vacuum system.

Applications

Fomblin fluids are suggested for applications requiring the highest quality vacuum such as in scanning electron and transmission microscopes, mass spectrometers, particle accelerators, ion implantation, plasma and vapor deposition processes.

In addition, it is suggested for pumps handling reactive gases such as UF6, F2, oxygen, ozone and tritium, as the fluid can be used in direct contact with these gases without reaction and fluid degradation.

 

 


A&J Vacuum repairs / rebuilds and services all Vacuum Pumps, including Turbo Vacuum Pumps and Rotary Vane Pumps, Pumping Stations.  Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Solvay Solexis Fomblin PFPE, Y L-VAC 16/6 Grade Inhert Vacuum Pump Lubricant, 1 kg, 3617OB


Technical Data:

Density: 1.89g/cm3

Viscosity Measurement: 110

Kinematic Viscocity: 168 cSt

Vapor Pressure: 2.67E-9 bar @ 20 degrees Celsius

 

 


A&J Vacuum repairs / rebuilds and services all Vacuum Pumps, including Turbo Vacuum Pumps and Rotary Vane Pumps, Pumping Stations.  Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.